0550-7516155|Disclaimers|Sitemap中文RussianEnglish

Transmitter

Intelligent capacitive transmitter

1, 3351 intelligent capacitor transmitter introduction 3351 Intelligent capacitor transmitter is t
  • Tel:0550-7516155
  • Fax:0550-7513155
  • Email:ghdq@ghdqkj.com
Description

1, 3351 intelligent capacitor transmitter introduction


3351 Intelligent capacitor transmitter is the most widely used in foreign countries, the most mature technology capacitive sensor core, and the introduction of a full set of foreign production technology and technology, strict implementation of the quality management system 9001:2000 standard, the production of the latest series of pressure/differential pressure transmitter. Product modular design and full patch packaging, a number of exquisite unique plastic mold with advanced laser engraving means, making the product more compact and perfect.


3351 Intelligent capacitor transmitter for different domestic user requirements, intelligent series through the local button, the field can be reset or re-calibrate the range, through the hand device or communication software can also realize passive calibration and data configuration. According to the special needs of users, the intelligent series can reach the maximum wide range ratio (100:1) and high precision (0.075%).


2, 3351 intelligent capacitor type transmitter technical parameters


★ Accuracy:


Digital signal: ±0.05%


Analog signal: ±0.075% to ±0.2%


Micro range (≤ 1.5 kP a) : ± 0.2 %


Note: Accuracy ≤±0.2% for ranges < 10:1


Ambient temperature impact /28 ° C


Range ratio 1:1 to 10:1: ≤±0.2%


Micro range (≤1.5kP a) : ± 0.5%


▲ The installation position is affected


Zero affects up to 250Pa, can be corrected, no range impact.


★ Comprehensive performance (based on reference accuracy, ambient temperature, static pressure effect and other comprehensive errors) in the transmitter


1:1 range, 28℃ temperature variation, 6.9MPa, static pressure is ±0.25%.


Vibration effect (except micro range)


Test less than 15 to 2000Hz on any axis relevant to piping installation process conditions


Plus or minus 0.1% F.S


Power supply influence


Less than 0.005%/V


Static pressure effect (differential pressure transmitter)


Zero error (can be eliminated at static pressure)


Static pressure ranges from 0 to 13.7MPa, ±0.2%/6.9MPa


Static pressure exceeds 13.7MPa, ±0.5%/6.9MPa


★ Measuring range error


Plus or minus 0.25% / 6.9 MPa


★ Stability


12 months, ±0.2%F.S, at a temperature change of 28℃,


The maximum static pressure is 6.9MPa and the range is 1:1.


Browse: