0550-7516155|Disclaimers|Sitemap中文RussianEnglish

Liquid level gauge

Magnetic pulse, magnetostriction, liquid level meter

● Working principle: Working principle of magnetostrictive liquid level sensor: When the initial p
  • Tel:0550-7516155
  • Fax:0550-7513155
  • Email:ghdq@ghdqkj.com
Description

● Working principle:


Working principle of magnetostrictive liquid level sensor: When the initial pulse is transmitted in the waveguide wire, a rotating magnetic field advancing along the direction of the waveguide wire is generated. When the magnetic field meets the permanent magnetic field in the magnetic ring or float, magnetostrictive effect is generated, which makes the waveguide wire twist. This twist is sensed by the pickup mechanism installed in the electronic bin and converted into the corresponding current pulse, and the time difference between the two pulses can be calculated through the electronic circuit to accurately measure the displacement and liquid level of the measured.


● Application scope and characteristics:


The product uses imported chips and advanced technology production, through the improvement of the company's technical personnel, the product design is reasonable, easy to install, exquisite structure, strong environmental adaptability, do not need regular re-marking and maintenance. It has the advantages of high precision, good stability, high reliability, various output signals, long service life, safety and reliability.


Widely used in industrial process control, oil processing, pharmaceutical, food processing, water treatment, gas station underground inventory in the field of liquid level, temperature, density, interface conditions and other physical parameters monitoring, alarm and control.


● Main performance parameters:


01, range: 0-6 meters, $2 can be customized according to user requirements $3;


02, working power supply: 24VDC;


03, signal output: 4-20mA standard current signal;


04, measurement accuracy: ±1mm or 0.3%FS$2 current output type $3;


05, working pressure: ≤ 4.0Mpa;


06, medium requirements: density ≥0.5g/cm3, viscosity ≤0.005Pa.s;


07, working temperature: -25~+80 ℃;


08, repeatability error: better than 0.01%FS;


09, resolution: better than 0.01%FS


10. Hysteresis: better than 0.01%FS


11, temperature effect: ±0.007%FS/ ℃


12, zero adjustment range: 20%FS


13, full scale adjustment range: 20%FS


14, frequency response time: 0.2~5ms $2 according to the size of the range $3;


15, connection form: flange connection;


16, explosion-proof mark: flameproof type: EXdⅡ BT4


17. Shell protection grade: IP65


18, the pressure of the measuring rod: ≤34Mpa