Regulating instrument

Electronic regulator

Product introduction: (general part) Type: disc mounted setting accuracy: 1.O level setting mode: d
  • Tel:0550-7516155
  • Fax:0550-7513155
  • Email:ghdq@ghdqkj.com
Description

Product introduction: (general part) Type: disc mounted setting accuracy: 1.O level setting mode: dial, four significant digits. If any. A surname. , “ Eg. The first digit of the range is a sign bit and the first digit is three significant digits.


Repeatability error: ± Three numbers


Deviation indication error: < 10% of the full range of the deviation table


Cold end compensation: included (TA-041 none)


Coupling protection: When the thermocouple is disconnected, the deviation table pointer should be able to go beyond the end of the deviation line.


Operating environment: No vibration, no corrosive gas, the temperature is O ~ 50℃, and the relative humidity is not more than 85%.


Power supply: 220V&plusmn; 10pc 50Hz


Weight: <4.2kg


External resistance: The table used with thermal resistance, external adjustment resistance for two 5&Omega;


Bit type or upper and lower limit alarm


Output: Relay contact 220V 3A(non-inductive load)


Alarm action: the insensitive area is not greater than the deviation table O. 5%


Sensitivity: < 0.5%


Two-position PID


Control accuracy: 0.5%


Cycle: 40&plusmn; 10 seconds


Adjusting parameters: P: 10-300% &times; 0.9 & times; (360&times; 10V/full electric range &times; K)&times; 100%


I: 0.25 to 7 points D: 0 to 1.5 points


Output: Relay contact 220V 3A(non-inductive load)


Three-position PI


Sensitivity: 0.3%


Adjusting parameters: : P: 0.5% ~ (Ty&times; 2250 / full electric range &times; K)&times; 100N T: 0.5 ~ 14 points


Output: relay contact 220V 3A(non-inductive load)220V 3A(inductive load), instrument panel is provided with a manual switch and manual operation button continuous PID


Sensitivity: 0.1%


Regulator parameters: P: 10 ~ 300% I: 0.25 ~ 7 min D: 0 ~ 1.5 min


Output: O ~ 10mA.DC(load 1K&Omega;) Instrument panel is equipped with manual automatic switching switch and manual operation button, manual D automatic undisturbed switching when the deviation is zero.