Electronic regulator
- Tel:0550-7516155
- Fax:0550-7513155
- Email:ghdq@ghdqkj.com
Description
TEM series electronic regulator is an electronic automatic detection and adjustment instrument, which can be used with various thermocouples, thermal resistance and DC signal transmitter to measure and control temperature and other parameters. If the instrument is equipped with an alarm device, it can alarm the measured object over the limit. This series of instruments are widely used in plastics, printing and dyeing, food processing, metal processing, medical, petroleum, chemical, electronic and other industrial sectors and other need to adjust the temperature occasions. This series of instruments are disk-mounted instruments. Because of their compact shape, they can be mounted directly on the equipment. Meters are cheap. The circuit of thermocouple instrument has the function of breaking protection. In the series of instruments, there are two position adjustment, time proportional adjustment and other varieties for choice, to ensure the automatic control of the production process.
Technical parameter
Setting range: full scale
Set base error: no more than 1.0% FS
Indicating range: set value plus or minus 20% FS, directly indicating the measured temperature
Indicating basic error: not more than ± 1.5% FS
Indicates insensitive area: no more than 0.5% FS
Engraving: Circular dial, scale range 245. , arc length 130mm
Two-position adjustment: switch difference ≤ 1.0%
Time ratio adjustment: the ratio with 1 ~ 10% adjustable
The on-off period is adjustable from 10 to 60 s
The time ratio can be adjusted manually
Over-limit alarm: the alarm value can be adjusted when the measured signal exceeds the set value of adjustment about 5% of the full range
The warning range is not more than 2% FS
Relay contact capacity: Adjusting relay AC 220V
3A (resistance)
1A(Sensibility)
Alarm relay AC 220V
0.5A(resistance)
Power source: AC 220V 50Hz
Input rated resistance: thermocouple 100Ω There is no need to adjust the internal heat distribution resistance. The resistance value of each wire is equal and less than 2&Omega. Power consumption: about 3W
Working environment: Temperature O ~ 50'℃, relative humidity 30 ~ 85%
Weight: about 1 kg